AX-2025-018864
Endotoxin tested twice on this lot with varying EU/mg spread. Endotoxin variability in retained samples is larger than most labs acknowledge and the single measurement here is not definitive.
AX-2025-019238
7.53 EU/mg but the material was passed through a sterile sterile filter. Some filters leach endotoxins; the measurement does not distinguish material from filter contribution.
AX-2024-005033
7.77 EU/mg from an older lot. Endotoxins are heat-stable and drift is rare. If this matches fresh-lot median from the same supplier, the number is stable.