AssayIndex
The index

Corrections log

Every change made to a published figure since the index opened, with both values and the reason. 10 entries. A short log is not evidence of accuracy — it is evidence of how much has been checked — and the index would rather this page were longer than that it were empty.

10 correctionssince 2024-Q1nothing silently amended
DateRecord or tableFieldWasNowWhy
2026-07-12AX-2026-041286lotSSA26H4471SSA26H4417Transcription error at intake; digits transposed against the submitted certificate. The record was attached to a batch that does not exist and has been re-attached.
2026-06-03batch rollups (14 records)coa_divergence_ppcomputed against the meancomputed against the medianDivergence was being computed against the mean of independent results on lots with three or more assays, contrary to what /suppliers/methodology/ stated. Fourteen batch pages changed by up to 0.08 pp.
2026-04-21AX-2025-018884endotoxin_eu_mg11.41.14Decimal error transcribing a gel-clot result. The record had been flagged AX-R08 in error and the flag is withdrawn.
2026-02-08compound registry — 3 compoundsmono_mass_daaverage massmonoisotopic massThree compounds carried an average mass in the monoisotopic field, producing apparent ppm errors of several hundred on every record referencing them. Twenty-two records had their AX-R01 flag withdrawn.
2025-11-14AX-2025-018201sample_sourcebuyer-sourcedsupplier-suppliedSubmitter clarified that the vial was provided by the supplier rather than purchased. Reclassified, and the supplier scorecard recomputed.
2025-09-02all quarterly aggregatesmedian_purity_pctincluded method-limited recordsexcludes method-limited recordsRecords marked method-limited were being included in class aggregates, inflating incretin medians by an estimated 0.04 pp. The exclusion is now applied at aggregation.
2025-05-27AX-2024-004902compound_slugmelanotan-iipt-141A unit-resolution identity confirmation had been recorded against the wrong member of a 1 Da pair. Re-assay at high resolution established the compound. The record now carries a note explaining why it could not have been distinguished originally.
2025-03-19suppliers.csvestablishedblank for 4 supplierspopulatedFour suppliers publish an establishment year that had not been transcribed. Populated from their own published material.
2024-12-11AX-2024-004117 and 6 otherswater_pctas reportedas reported, flaggedSeven records reported water below 0.4 %, which is below the working limit of coulometric Karl Fischer for these sample sizes. Values retained, and a note added stating that they should be read as "below the limit of quantitation" rather than as measurements.
2024-08-05peak tables — 31 recordslargest_impurity_pctunorderedordered descendingThirty-one peak tables listed impurities by retention time rather than descending area, so the first row was not the largest single impurity as the column header claimed. Re-ordered.

How to report an error

Errors are reported the same way records are submitted — see the submission page. A useful report names the record ID, the field, what the value should be and how you know. The index will correct a demonstrated error in a published figure within a day and log it here.

What is not a correction

A disagreement between two laboratories is not an error and does not get corrected. It gets published on the batch page as a disagreement, because that is what it is. See the data policy on disputes.