5.37 EU/mg is elevated relative to the index median and the record shows no depyrogenation step. If this material will be reconstituted in aqueous buffer for any downstream use, that endotoxin load is a risk.
multiple_compare
Twenty suppliers, sixty-six compounds, and the multiplicity problem.
Section 1
Contribution
Comments technically on records submitted by others. Annotations are signed and are not moderated for agreement.
Records submitted
0
n=0
Annotations
3
n=3
Median purity submitted
suppressed
n=0
n<3 — see individual records
Suppliers covered
0
n=0
This handle has submitted no records. Annotators comment on other people's submissions and are not required to submit.
Section 2
Annotations
Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it.
Endotoxin determined but the LAL method is not stated. Kinetic chromogenic and gel-clot give different results and different sensitivity. The value cannot be interpreted without knowing which.
8.03 EU/mg but the material was passed through a sterile sterile filter. Some filters leach endotoxins; the measurement does not distinguish material from filter contribution.