State of the index · 2024-Q4

Impurity fingerprinting: nineteen bulks, twenty-nine labels

Named-impurity data reaches critical mass and the index can identify lots that are the same material sold twice.

434 records76 batchesmedian 98.97 %321 flagged

Two independent syntheses of the same peptide do not produce the same four impurities at the same four levels. Two aliquots of one bulk do. With enough named-impurity data, that becomes a usable identification method, and in 2024-Q4 the index had enough.

The matching rule

A match requires identical impurity identities, identical rank order, at least four named impurities, and each level agreeing within 0.05 % area or 10 % relative, whichever is larger. The rule is deliberately strict; a looser rule produces coincidental matches on compounds whose impurity profiles are dominated by one or two universal species.

Twenty-nine matches were established, spanning nineteen distinct bulks. Eleven of the nineteen trace to one manufacturer-tier supplier, which is the expected result in a contract-synthesis market and not a criticism of anyone.

Two consequences the index had to handle

  1. Independence. Treating two aliquots of one bulk as two independent observations overstates the evidence. Matched batches are now counted once in index aggregates and cross-linked on both batch pages.
  2. Comparison. A buyer choosing between two suppliers on the strength of their published test results should know when those results describe the same material. Both batch pages now say so explicitly.

What fingerprinting requires, and why most data cannot supply it

A totals-only certificate cannot be fingerprinted. Of the six laboratories contributing to the index, one reports related substances by name with retention times as standard; the others report totals, or names only above a high threshold. All but four of the twenty-nine matches come from that one laboratory's data.

This is the strongest argument the index can make for named-impurity reporting. A total impurity figure tells you how much is wrong. A named table tells you what is wrong, whether it is a synthesis or a storage problem, and which other lots in the world are the same material.

Rule added

Rule AX-R09 was published this quarter with its predicate stated in full. It is classified as a low-severity flag because a shared bulk is not improper — it is an evidentiary caveat rather than a quality finding.

Appendix

Quarter in numbers

Records submitted 434 n=434
Batches 76 n=76
Median purity 98.97% n=434
IQR 1.18pp n=434
Suppliers represented 19 n=434
Compounds represented 34 n=434
Records flagged 321 n=434
Buyer-sourced share 12.4% n=434

Every record submitted in 2024-Q4 →