AssayIndex

BCH-2508-A7959

Tirzepatide · 60 mg declared · Bachem Holding (Suzhou) Co., Ltd. · manufactured 04 Aug 2025

CHARACTERISED
Lot code
BCH-2508-A7959
Supplier
BCH — Bachem Holding (Suzhou) Co., Ltd.
Compound
Tirzepatide
Compound class
Incretin analogues and co-agonists
Declared label claim
60mg
Manufacture date
04 Aug 2025
Index quarter
2025-Q3
Independent assays
12
Laboratories involved
Janoshik, Medutest, Nordanalyt, VendorInvestigate
Provenance mix
Buyer-sourced ×9 · Supplier-supplied ×2 · Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 12
Median purity 98.91% n=12
Spread (max − min) 1.21pp n=12
Standard deviation 0.326pp n=12
95.796.597.298.098.799.5100.2This lot (BCH-2508-A7959)This lot (BCH-2508-A7959): Q1 98.81, median 98.91, Q3 99.18, n=12n=12All TirzepatideAll Tirzepatide: Q1 97.99, median 98.54, Q3 98.98, n=706outlier 96.03outlier 96.21outlier 96.46outlier 96.47n=706 Purity (% area)
Figure 1. This lot's independent purity results against the whole Tirzepatide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 97.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 12

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-021325BCH-2508-A7959Janoshik2025-Q398.775.1491.5Buyer-sourced1FAIL
AX-2025-021326BCH-2508-A7959Medutest2025-Q398.905.13102.7Laboratory-retained0PASS
AX-2025-021327BCH-2508-A7959Medutest2025-Q399.285.5089.2Buyer-sourced1MARGINAL
AX-2025-021328BCH-2508-A7959Janoshik2025-Q398.825.30102.9Buyer-sourced0PASS
AX-2025-021329BCH-2508-A7959Janoshik2025-Q398.345.2394.3Buyer-sourced0PASS
AX-2025-021330BCH-2508-A7959Janoshik2025-Q398.895.09Buyer-sourced0PASS
AX-2025-021331BCH-2508-A7959Nordanalyt2025-Q399.154.76101.2Supplier-supplied0PASS
AX-2025-021332BCH-2508-A7959Janoshik2025-Q398.915.40Buyer-sourced1MARGINAL
AX-2025-021333BCH-2508-A7959Janoshik2025-Q399.305.52102.9Supplier-supplied0PASS
AX-2025-021334BCH-2508-A7959Medutest2025-Q399.554.7495.4Buyer-sourced0PASS
AX-2025-021335BCH-2508-A7959Janoshik2025-Q398.625.2790.4Buyer-sourced0PASS
AX-2025-021336BCH-2508-A7959VendorInvestigate2025-Q398.985.1994.3Buyer-sourced0PASS
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik798.77, 98.82, 98.34, 98.89, 98.91, 99.30, 98.6298.8230min+0.0098.82
Medutest398.90, 99.28, 99.5599.2825min+0.0899.20
Nordanalyt199.1599.1535min+0.0299.13
VendorInvestigate198.9898.9832min-0.1199.09

This lot contributes 6 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.7298.77divergence -0.19 pp vs batch median
Total impurities (% area)1.281.23
Largest single impurity (% area)0.730.77
Water (%)not stated5.14
Counter-ion (%)not stated5.75
Peptide content (%w/w)not stated88.79
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-Aib2 analogue12 / 120.290.03–1.03
tirzepatide dimer12 / 120.080.03–0.12
[D-Aib13]-diastereomer12 / 120.070.02–0.23
trifluoroacetyl adduct (+96 Da)6 / 120.210.18–0.29
truncated (3-39)6 / 120.090.05–0.16
C20 diacid mono-amide6 / 120.580.29–0.63
des-Gly deletion (−57 Da)5 / 120.060.06–0.07
Met(O) sulfoxide (+16 Da)3 / 120.020.02–0.03
Section 7