AssayIndex

SGN-2504-A9926

Triptorelin · 5 mg declared · Sangon Biotech (Shanghai) Co., Ltd. · manufactured 30 Apr 2025

CHARACTERISED
Lot code
SGN-2504-A9926
Supplier
SGN — Sangon Biotech (Shanghai) Co., Ltd.
Compound
Triptorelin
Compound class
Hypothalamic and posterior-pituitary hormones
Declared label claim
5mg
Manufacture date
30 Apr 2025
Index quarter
2025-Q2
Independent assays
6
Laboratories involved
Nordanalyt, Janoshik, VendorInvestigate, PeptideMeter
Provenance mix
Buyer-sourced ×2 · Supplier-supplied ×4
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 6
Median purity 98.40% n=6
Spread (max − min) 0.72pp n=6
Standard deviation 0.241pp n=6
97.798.198.598.999.399.7100.1This lot (SGN-2504-A9926)This lot (SGN-2504-A9926): Q1 98.31, median 98.40, Q3 98.49, n=6outlier 98.01n=6All TriptorelinAll Triptorelin: Q1 98.31, median 98.47, Q3 99.08, n=10n=10 Purity (% area)
Figure 1. This lot's independent purity results against the whole Triptorelin record set in the index. The vertical line is the index acceptance specification for the hypothalamic and posterior-pituitary hormones class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 6

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020761SGN-2504-A9926Nordanalyt2025-Q298.415.4989.8Supplier-supplied1FAIL
AX-2025-020762SGN-2504-A9926Janoshik2025-Q298.524.72106.0Supplier-supplied0PASS
AX-2025-020763SGN-2504-A9926Janoshik2025-Q298.395.04Buyer-sourced0FAIL
AX-2025-020764SGN-2504-A9926VendorInvestigate2025-Q298.014.9297.8Buyer-sourced0FAIL
AX-2025-020765SGN-2504-A9926PeptideMeter2025-Q298.284.54106.3Supplier-supplied1FAIL
AX-2025-020766SGN-2504-A9926PeptideMeter2025-Q298.734.8199.0Supplier-supplied1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Nordanalyt198.4198.4135min+0.0298.39
Janoshik298.52, 98.3998.4530min+0.0098.45
VendorInvestigate198.0198.0132min-0.1198.12
PeptideMeter298.28, 98.7398.5028min-0.0598.55

This lot contributes 6 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.5598.41divergence +0.15 pp vs batch median
Total impurities (% area)1.451.59
Largest single impurity (% area)not stated0.77
Water (%)4.15.49
Counter-ion (%)not stated2.77
Peptide content (%w/w)91.190.90
Endotoxin (EU/mg)0.47not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
ring-opened pGlu (+18 Da)6 / 60.460.10–0.83
oxidised Trp (+16 Da)6 / 60.270.07–0.47
[L-Trp6]-diastereomer (gonadorelin analogue)6 / 60.590.27–1.41
des-Gly10-NH2 (−74 Da)6 / 60.170.12–0.32
Section 7

What this rollup does not establish