AssayIndex

TFC-2410-N7616

LL-37 · 1 mg declared · Tianjin Finder Chemical Co., Ltd. · manufactured 15 Oct 2024

CHARACTERISED
Lot code
TFC-2410-N7616
Supplier
TFC — Tianjin Finder Chemical Co., Ltd.
Compound
LL-37
Compound class
Tissue-repair and immunomodulatory peptides
Declared label claim
1mg
Manufacture date
15 Oct 2024
Index quarter
2025-Q1
Independent assays
10
Laboratories involved
VendorInvestigate, PeptideMeter, Nordanalyt, Janoshik
Provenance mix
Buyer-sourced ×2 · Supplier-supplied ×8
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 10
Median purity 98.17% n=10
Spread (max − min) 1.12pp n=10
Standard deviation 0.289pp n=10
97.397.898.398.799.299.7100.1This lot (TFC-2410-N7616)This lot (TFC-2410-N7616): Q1 98.04, median 98.16, Q3 98.29, n=10outlier 97.51n=10All LL-37All LL-37: Q1 98.18, median 98.61, Q3 99.17, n=36n=36 Purity (% area)
Figure 1. This lot's independent purity results against the whole LL-37 record set in the index. The vertical line is the index acceptance specification for the tissue-repair and immunomodulatory peptides class, 96.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 10

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019357TFC-2410-N7616VendorInvestigate2025-Q198.064.09107.5Buyer-sourced1MARGINAL
AX-2025-019358TFC-2410-N7616PeptideMeter2025-Q198.193.79Supplier-supplied1MARGINAL
AX-2025-019359TFC-2410-N7616Nordanalyt2025-Q198.253.67Supplier-supplied2FAIL
AX-2025-019360TFC-2410-N7616PeptideMeter2025-Q198.143.8696.6Supplier-supplied1MARGINAL
AX-2025-019361TFC-2410-N7616Janoshik2025-Q198.303.9894.9Supplier-supplied1MARGINAL
AX-2025-019362TFC-2410-N7616PeptideMeter2025-Q197.514.3395.5Supplier-supplied2FAIL
AX-2025-019363TFC-2410-N7616Janoshik2025-Q198.334.18Supplier-supplied1MARGINAL
AX-2025-019364TFC-2410-N7616Janoshik2025-Q198.034.59104.4Buyer-sourced1MARGINAL
AX-2025-019365TFC-2410-N7616Janoshik2025-Q197.994.0392.0Supplier-supplied0PASS
AX-2025-019366TFC-2410-N7616Nordanalyt2025-Q198.633.6298.1Supplier-supplied1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
VendorInvestigate198.0698.0632min-0.1198.17
PeptideMeter398.19, 98.14, 97.5198.1428min-0.0598.19
Nordanalyt298.25, 98.6398.4435min+0.0298.42
Janoshik498.30, 98.33, 98.03, 97.9998.1630min+0.0098.16

This lot contributes 6 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.8598.06divergence +0.68 pp vs batch median
Total impurities (% area)1.151.94
Largest single impurity (% area)0.741.01
Water (%)1.84.09
Counter-ion (%)not stated5.91
Peptide content (%w/w)not stated89.83
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
deamidated (+1 Da)10 / 100.780.37–1.05
truncated (1-31)10 / 100.660.56–1.03
trifluoroacetyl adduct (+96 Da)10 / 100.140.12–0.24
des-Leu1 (−113 Da)10 / 100.100.08–0.17
aggregated multimer10 / 100.130.04–0.37
Section 7