AssayIndex

WXT-2408-P5247

MK-677 (Ibutamoren mesylate) · 1000 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · manufactured 02 Aug 2024

SINGLE TESTSHARED BULK
Lot code
WXT-2408-P5247
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Declared label claim
1000mg
Manufacture date
02 Aug 2024
Index quarter
2024-Q4
Independent assays
1
Laboratories involved
Janoshik
Provenance mix
Supplier-supplied ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 99.43% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
96.997.498.098.599.199.6100.2All MK-677 (Ibutamoren mesylate)All MK-677 (Ibutamoren mesylate): Q1 98.51, median 99.37, Q3 99.77, n=152n=152 Purity (% area)
Figure 1. This lot's independent purity results against the whole MK-677 (Ibutamoren mesylate) record set in the index. The vertical line is the index acceptance specification for the non-peptide adjuncts class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-005427WXT-2408-P5247Janoshik2024-Q499.435.0393.9Supplier-supplied2FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik199.4399.4330min+0.0099.43

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.3899.43divergence -0.05 pp vs batch median
Total impurities (% area)0.620.57
Largest single impurity (% area)0.460.22
Water (%)2.65.03
Counter-ion (%)not stated12.90
Peptide content (%w/w)not stated81.41
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
sulfonamide hydrolysis product (+18 Da)1 / 10.22
free base (des-mesylate, −96 Da)1 / 10.20
spiroindane regioisomer1 / 10.09
residual DMF (process solvent)1 / 10.06
Section 6

Shared-bulk links

Rule AX-R09. Where impurity fingerprints and latent composition match across companies, the index treats the material as one bulk and counts it once in aggregates.

LotSold byRoleReportsMedian purity
GLBI-2501-Y8359GL Biochemparent bulk1398.52
WXT-2408-P5247WXTthis lot199.43
Section 7

What this rollup does not establish