AssayIndex

WXT-2605-B5313

L-Glutathione (reduced) · 600 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · manufactured 10 May 2026

SINGLE TEST
Lot code
WXT-2605-B5313
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Compound
L-Glutathione (reduced)
Compound class
Short bioregulator peptides
Declared label claim
600mg
Manufacture date
10 May 2026
Index quarter
2026-Q3
Independent assays
1
Laboratories involved
PeptideMeter
Provenance mix
Supplier-supplied ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 97.39% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
96.196.897.598.298.899.5100.2All L-Glutathione (reduced)All L-Glutathione (reduced): Q1 98.58, median 99.00, Q3 99.57, n=122outlier 96.39n=122 Purity (% area)
Figure 1. This lot's independent purity results against the whole L-Glutathione (reduced) record set in the index. The vertical line is the index acceptance specification for the short bioregulator peptides class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043461WXT-2605-B5313PeptideMeter2026-Q397.396.92102.2Supplier-supplied0FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
PeptideMeter197.3997.3928min-0.0597.44

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)97.8797.39divergence +0.48 pp vs batch median
Total impurities (% area)not stated2.61
Largest single impurity (% area)not stated1.26
Water (%)not stated6.92
Counter-ion (%)not statedN/A
Peptide content (%w/w)not stated92.86
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
cysteinyl-glycine (−129 Da)1 / 11.26
γ-Glu-Cys (−57 Da)1 / 10.77
glutathione disulfide (GSSG, +305 Da)1 / 10.40
S-sulfonate adduct (+80 Da)1 / 10.18
Section 7

What this rollup does not establish