AssayIndex

CPC-2502-C1391

Adipotide · 2 mg declared · Chinese Peptide Company Co., Ltd. · manufactured 21 Feb 2025

PARTIALLY CHARACTERISED
Lot code
CPC-2502-C1391
Supplier
CPC — Chinese Peptide Company Co., Ltd.
Compound
Adipotide
Compound class
Metabolic and mitochondrial peptides
Declared label claim
2mg
Manufacture date
21 Feb 2025
Index quarter
2025-Q2
Independent assays
2
Laboratories involved
Nordanalyt, Janoshik
Provenance mix
Buyer-sourced ×1 · Supplier-supplied ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 2
Median purity 97.61% n=2
Spread (max − min) 0.87pp n=2
Standard deviation n<3 n=2
96.897.397.898.398.899.299.7This lot (CPC-2502-C1391)This lot (CPC-2502-C1391): Q1 97.39, median 97.61, Q3 97.82, n=2n=2All AdipotideAll Adipotide: Q1 98.23, median 98.59, Q3 98.92, n=16outlier 97.04outlier 97.17n=16 Purity (% area)
Figure 1. This lot's independent purity results against the whole Adipotide record set in the index. The vertical line is the index acceptance specification for the metabolic and mitochondrial peptides class, 96.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 2

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020846CPC-2502-C1391Nordanalyt2025-Q297.175.1590.6Buyer-sourced1MARGINAL
AX-2025-020847CPC-2502-C1391Janoshik2025-Q298.045.51106.3Supplier-supplied2MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Nordanalyt197.1797.1735min+0.0297.15
Janoshik198.0498.0430min+0.0098.04

This lot contributes 1 paired comparison to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)97.9397.17divergence +0.32 pp vs batch median
Total impurities (% area)2.782.83
Largest single impurity (% area)1.991.97
Water (%)4.45.15
Counter-ion (%)4.35.29
Peptide content (%w/w)90.788.85
Endotoxin (EU/mg)not stated0.23
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
truncated KLAKLAK repeat (−781 Da)2 / 21.140.30–1.97
disulfide-scrambled isomer2 / 20.380.18–0.57
open-chain (reduced disulfide, +2 Da)2 / 20.640.17–1.11
trifluoroacetyl adduct (+96 Da)2 / 20.240.12–0.37
Section 7

What this rollup does not establish