AssayIndex

SGN-2510-P9566

GHRP-6 · 2 mg declared · Sangon Biotech (Shanghai) Co., Ltd. · manufactured 08 Oct 2025

CHARACTERISED
Lot code
SGN-2510-P9566
Supplier
SGN — Sangon Biotech (Shanghai) Co., Ltd.
Compound
GHRP-6
Compound class
Growth-hormone axis peptides
Declared label claim
2mg
Manufacture date
08 Oct 2025
Index quarter
2026-Q1
Independent assays
5
Laboratories involved
Janoshik, VendorInvestigate, Nordanalyt
Provenance mix
Buyer-sourced ×2 · Supplier-supplied ×3
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 5
Median purity 98.68% n=5
Spread (max − min) 0.77pp n=5
Standard deviation 0.343pp n=5
97.898.198.598.999.399.7100.1This lot (SGN-2510-P9566)This lot (SGN-2510-P9566): Q1 98.44, median 98.68, Q3 99.02, n=5n=5All GHRP-6All GHRP-6: Q1 99.15, median 99.65, Q3 99.93, n=169outlier 97.92n=169 Purity (% area)
Figure 1. This lot's independent purity results against the whole GHRP-6 record set in the index. The vertical line is the index acceptance specification for the growth-hormone axis peptides class, 99.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 5

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043206SGN-2510-P9566Janoshik2026-Q198.681.32Supplier-supplied1FAIL
AX-2026-043207SGN-2510-P9566VendorInvestigate2026-Q198.441.78Buyer-sourced1FAIL
AX-2026-043208SGN-2510-P9566Nordanalyt2026-Q199.022.0899.1Supplier-supplied1MARGINAL
AX-2026-043209SGN-2510-P9566Janoshik2026-Q199.151.3492.6Supplier-supplied1MARGINAL
AX-2026-043210SGN-2510-P9566Janoshik2026-Q198.381.8091.4Buyer-sourced1FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik398.68, 99.15, 98.3898.6830min+0.0098.68
VendorInvestigate198.4498.4432min-0.1198.55
Nordanalyt199.0299.0235min+0.0299.00

This lot contributes 3 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.4098.68divergence +0.72 pp vs batch median
Total impurities (% area)not stated1.32
Largest single impurity (% area)not stated0.65
Water (%)not stated1.32
Counter-ion (%)5.77.31
Peptide content (%w/w)90.2not determined
Endotoxin (EU/mg)not stated0.40
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
[D-Trp]-epimer5 / 50.490.18–0.80
oxidised Trp (+16 Da)5 / 50.450.32–0.82
des-Lys (−128 Da)5 / 50.140.09–0.26
bis-oxidised Trp (+32 Da)5 / 50.110.08–0.14
Section 7

What this rollup does not establish