Survodutide by laboratory
The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for Survodutide, with a class minimum gradient of 25 min, the method is a live explanation.
| Laboratory | Reports | Gradient | MS resolution | Median purity % | Published bias (pp) | Bias-adjusted | Method suitability |
|---|---|---|---|---|---|---|---|
| Janoshik | 34 | 30min | High | 98.78 | +0.00 | 98.78 | ADEQUATE |
| PeptideMeter | 13 | 28min | High | 98.25 | -0.05 | 98.30 | ADEQUATE |
| Medutest | 6 n=6 | 25min | Unit | 98.79 | +0.08 | 98.71 | ADEQUATE |
| VendorInvestigate | 6 n=6 | 32min | High | 98.53 | -0.11 | 98.64 | ADEQUATE |
| Kestrel | 5 n=5 | 15min | Unit | 99.37 | +0.24 | 99.13 | BELOW CLASS MINIMUM |
| Nordanalyt | 4 n=4 | 35min | High | 98.09 | +0.02 | 98.07 | ADEQUATE |