TB-500 by laboratory
The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for TB-500, with a class minimum gradient of 15 min, the method is a live explanation.
| Laboratory | Reports | Gradient | MS resolution | Median purity % | Published bias (pp) | Bias-adjusted | Method suitability |
|---|---|---|---|---|---|---|---|
| Janoshik | 178 | 30min | High | 99.53 | +0.00 | 99.53 | ADEQUATE |
| PeptideMeter | 59 | 28min | High | 99.44 | -0.05 | 99.49 | ADEQUATE |
| Medutest | 39 | 25min | Unit | 99.70 | +0.08 | 99.62 | ADEQUATE |
| VendorInvestigate | 34 | 32min | High | 99.00 | -0.11 | 99.11 | ADEQUATE |
| Nordanalyt | 28 | 35min | High | 99.69 | +0.02 | 99.67 | ADEQUATE |
| Kestrel | 18 | 15min | Unit | 99.48 | +0.24 | 99.24 | ADEQUATE |