AssayIndex

AX-2026-043700

MK-677 (Ibutamoren mesylate) · 500 mg declared · Bachem Holding (Suzhou) Co., Ltd. · lot BCH-2601-G7291

FAILPURITY ONLY
Report ID
AX-2026-043700
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
BCH — Bachem Holding (Suzhou) Co., Ltd.
Batch / lot
BCH-2601-G7291
Declared label claim
500mg
Laboratory
Medutest
Assay date
11 Mar 2026
Submitted
04 Apr 2026
Quarter
2026-Q1
Submitter
Contributor #V-2091
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm97.98% area≥ 98.5FAIL
Total impuritiesRP-HPLC, sum of reported peaks2.02% area≤ 1.5FAIL
Largest single impurityRP-HPLC — O-desmethyl metabolite analogue (−14 Da)0.91% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance82.42%w/wNOT TESTED
Target-compound contenttotal peptide content × purity80.76%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen551.63mg500 mg declaredNOT TESTED
Recovered target peptidegross fill × target content445.496mg500 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim89.1%90.0 – 110.0FAIL
Water contentKarl Fischer, coulometric, duplicate3.59%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography13.55%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.44%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.892.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient11.76min11.73 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.080.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²53,226≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.16no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02144428864328576 MK-677 (Ibutamoren mesylate)11.76 min · 97.98 % 11.334.93 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 53,226, and skew follows the reported asymmetry factor of 1.08. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.91 % impurity against a 97.98 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak11.764,762,13297.98
2O-desmethyl metabolite analogue (−14 Da)11.3344,2290.91-14.016
3spiroindane regioisomer12.1322,3570.460.000
4free base (des-mesylate, −96 Da)11.7912,6370.26-96.011
5sulfonamide hydrolysis product (+18 Da)11.049,7210.20+18.011
6residual DMF (process solvent)4.939,2350.19-551.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer3.59
Counter-ion (mesylate)ion chromatography13.55
Residual solvent + inorganic residueestimated0.44
Total peptide contentby difference82.42
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.8497.98divergence -0.14 pp vs batch median
Total impurities (% area)2.162.02
Largest single impurity (% area)1.320.91
Water (%)2.03.59
Counter-ion (%)3.113.55
Peptide content (%w/w)97.682.42
Endotoxin (EU/mg)1.00not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 32 d) → laboratory (courier, dry ice, 7 d) → assay.
Assay date
11 Mar 2026
Submitted to the index
04 Apr 2026
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 5

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

desiccant_note
The packaging as received is part of the evidence on a retail purchase. Whether a desiccant was in the box is a fact about ordinary shipments, not about sample shipments.
iso_audit
A certification says what a process is supposed to do. A retail vial says what it did. Both are worth having and only one of them is a measurement.
ion_pair_ip
The resolution figure sits in the system-suitability block with no PASS or FAIL beside it. That is deliberate: the index reports it and adjudicates nothing against it.
baseline_noise
On a low-resolution pair the baseline between the peaks never reaches baseline, so any integration is an extrapolation. Stating which extrapolation was used is worth more than any threshold.
Section 7

Related records

Same batch — lot BCH-2601-G7291 n=7

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043697BCH-2601-G7291PeptideMeter2026-Q198.264.31Buyer-sourced1FAIL
AX-2026-043698BCH-2601-G7291Nordanalyt2026-Q197.673.9597.7Buyer-sourced1FAIL
AX-2026-043699BCH-2601-G7291PeptideMeter2026-Q198.093.9897.5Buyer-sourced1FAIL
AX-2026-043701BCH-2601-G7291Janoshik2026-Q197.974.13101.5Buyer-sourced1FAIL
AX-2026-043702BCH-2601-G7291Medutest2026-Q198.413.7192.0Laboratory-retained1FAIL
AX-2026-043703BCH-2601-G7291Janoshik2026-Q197.974.1497.4Buyer-sourced1FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041754FGPFGP-2604-K9878Janoshik2026-Q299.895.0693.8Buyer-sourced0FAIL
AX-2026-042619SWBSWB-2605-B6440Janoshik2026-Q299.303.05Buyer-sourced0FAIL
AX-2026-041756FGPFGP-2604-K9878Janoshik2026-Q299.624.4189.4Buyer-sourced1FAIL
AX-2026-041751FGPFGP-2604-K9878Janoshik2026-Q299.795.6988.7Buyer-sourced1FAIL
AX-2026-043676BCHBCH-2511-G7498Medutest2026-Q298.864.8199.6Buyer-sourced1FAIL
AX-2026-043678BCHBCH-2511-G7498Kestrel2026-Q298.743.73Buyer-sourced0FAIL
AX-2026-041753FGPFGP-2604-K9878Janoshik2026-Q299.935.7288.7Buyer-sourced1FAIL
AX-2026-043677BCHBCH-2511-G7498Janoshik2026-Q298.834.58Supplier-supplied0FAIL
Other recent BCH records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043691BPC-157BCH-2603-L7768Janoshik2026-Q398.665.12Supplier-supplied1MARGINAL
AX-2026-043693BPC-157BCH-2603-L7768PeptideMeter2026-Q397.825.2194.9Buyer-sourced0FAIL
AX-2026-043686BPC-157BCH-2603-L7768VendorInvestigate2026-Q397.645.27Buyer-sourced0FAIL
AX-2026-043695BPC-157BCH-2603-L7768Janoshik2026-Q397.615.42Buyer-sourced0FAIL
AX-2026-043726N-Acetyl Semax AmideBCH-2602-E8475Janoshik2026-Q397.899.67104.2Buyer-sourced0FAIL
AX-2026-043688BPC-157BCH-2603-L7768Janoshik2026-Q397.945.56Buyer-sourced0FAIL
AX-2026-043658BPC-157BCH-2603-G6644Janoshik2026-Q398.454.37101.8Supplier-supplied0PASS
AX-2026-043692BPC-157BCH-2603-L7768VendorInvestigate2026-Q397.605.61Buyer-sourced0FAIL