AssayIndex

AMB-2507-S5238

CJC-1295 (no DAC) · 2 mg declared · AmbioPharm, Inc. · manufactured 01 Jul 2025

CHARACTERISED
Lot code
AMB-2507-S5238
Supplier
AMB — AmbioPharm, Inc.
Compound
CJC-1295 (no DAC)
Compound class
Growth-hormone axis peptides
Declared label claim
2mg
Manufacture date
01 Jul 2025
Index quarter
2025-Q3
Independent assays
13
Laboratories involved
Medutest, Janoshik, Kestrel, PeptideMeter, Nordanalyt, VendorInvestigate
Provenance mix
Buyer-sourced ×13
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 13
Median purity 99.61% n=13
Spread (max − min) 0.49pp n=13
Standard deviation 0.184pp n=13
97.297.798.198.699.199.6100.1This lot (AMB-2507-S5238)This lot (AMB-2507-S5238): Q1 99.55, median 99.61, Q3 99.88, n=13n=13All CJC-1295 (no DAC)All CJC-1295 (no DAC): Q1 98.76, median 99.09, Q3 99.50, n=220outlier 97.36outlier 97.41outlier 97.52n=220 Purity (% area)
Figure 1. This lot's independent purity results against the whole CJC-1295 (no DAC) record set in the index. The vertical line is the index acceptance specification for the growth-hormone axis peptides class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 13

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019243AMB-2507-S5238Medutest2025-Q399.935.75Buyer-sourced0PASS
AX-2025-019244AMB-2507-S5238Janoshik2025-Q399.886.2089.1Buyer-sourced1MARGINAL
AX-2025-019245AMB-2507-S5238Janoshik2025-Q399.666.34103.5Buyer-sourced0PASS
AX-2025-019246AMB-2507-S5238Kestrel2025-Q399.935.70104.6Buyer-sourced0PASS
AX-2025-019247AMB-2507-S5238PeptideMeter2025-Q399.446.6095.8Buyer-sourced0PASS
AX-2025-019248AMB-2507-S5238Nordanalyt2025-Q399.615.78105.9Buyer-sourced0PASS
AX-2025-019249AMB-2507-S5238Janoshik2025-Q399.506.4589.9Buyer-sourced1MARGINAL
AX-2025-019250AMB-2507-S5238Kestrel2025-Q399.935.5888.9Buyer-sourced1MARGINAL
AX-2025-019251AMB-2507-S5238Medutest2025-Q399.595.6293.2Buyer-sourced0PASS
AX-2025-019252AMB-2507-S5238VendorInvestigate2025-Q399.465.95Buyer-sourced0PASS
AX-2025-019253AMB-2507-S5238VendorInvestigate2025-Q399.725.3996.7Buyer-sourced0PASS
AX-2025-019254AMB-2507-S5238PeptideMeter2025-Q399.555.8791.5Buyer-sourced0PASS
AX-2025-019255AMB-2507-S5238PeptideMeter2025-Q399.605.8394.0Buyer-sourced0PASS
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest299.93, 99.5999.7625min+0.0899.68
Janoshik399.88, 99.66, 99.5099.6630min+0.0099.66
Kestrel299.93, 99.9399.9315min+0.2499.69
PeptideMeter399.44, 99.55, 99.6099.5528min-0.0599.60
Nordanalyt199.6199.6135min+0.0299.59
VendorInvestigate299.46, 99.7299.5932min-0.1199.70

This lot contributes 15 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence +0.29 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)not stated0.04
Water (%)4.35.75
Counter-ion (%)3.33.75
Peptide content (%w/w)91.8not determined
Endotoxin (EU/mg)0.540.89
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
native GRF (1-29) (−59 Da)13 / 130.110.03–0.24
deamidated (+1 Da)12 / 130.070.03–0.16
truncated (1-24)10 / 130.110.04–0.20
des-Tyr1 (−163 Da)10 / 130.070.04–0.10
Section 7

What this rollup does not establish