AssayIndex
Supplier scorecard

AMB — AmbioPharm, Inc.

Beijing, CN · established 2003. The index holds 203 assay reports across 36 batches and 18 compounds, contributed by 6 laboratories. Every figure below is computed from those records and from nothing else.

203 reports36 batchesmedian purity 99.43 %documentation 93/100

Where AMB sells

AmbioPharm, Inc. sells from its own storefront. The link is marked nofollow and sponsored: it exists so the figures on this scorecard can be read against what the supplier itself publishes. The index is paid nothing for it and a link is not an assessment.

Visit AMB at ambiopharm.net →

Every figure above describes lots the index has seen. It says nothing about the lot you are offered, and the only check that does is the one on the certificate against the vial.

Block 1

Identification

Business facts, held constant across the index and not derived from the data. The index sells nothing and takes no supplier payment for placement; the storefront link below is marked nofollow and sponsored so a record can be checked against the seller, and is not a recommendation.

Legal name
AmbioPharm, Inc.
Short code in this index
AMB
Also known as
AMB · AmbioPharm · AmbioPharm Beijing · 安必奥医药
City
Beijing
Region
Beijing
Country
CN
Established
2003
First record in index
28 Jan 2024
Most recent record
09 Oct 2026
Block 1b

Dispatch and regional stock

Counted from the chain-of-custody line on this supplier's own records, which names the route each vial travelled to the laboratory, and from the on-record reviews below. The index has no sight of any supplier's warehouse network and publishes none.

Domestic-warehouse route 14.8% n=203
Retail, shipped to the buyer 79.3% n=203
Direct to the laboratory 0.5% n=203
Median courier leg, direct despatch suppressed n=1 n<3 — see individual records
Route to the laboratoryRecordsShare
Domestic warehouse despatch3014.8%
Retail purchase, shipped to the buyer12662.1%
Retail purchase via a third-party forwarder3517.2%
Supplier despatch direct to the laboratory10.5%
Laboratory retained-sample archive115.4%

Every record here carries a chain-of-custody line and that line names the route the vial travelled. Of the 203 AMB records the index holds, 30 reached the contributing laboratory from a domestic warehouse rather than as a cross-border consignment, covering 12 of the 18 compounds AMB is represented by here — Ipamorelin, AOD-9604, CJC-1295 (no DAC), GHRP-6, Semaglutide, Epitalon and 6 further compounds. Those are the AMB lines this index has actually seen arrive from regional stock, and they are a count of consignments rather than a stock listing: a line missing from them may simply never have been submitted for assay.

One contributor on the record below documents AMB stock held in Netherlands, with a transit of 9 working days against a quoted 10. Netherlands is the only regional stock location named anywhere in AMB's record here, and one consignment described by one buyer is exactly that. It is not a warehouse list and the index has not verified it.

The index measures nothing about lead time — it assays material, it does not buy it. What it has is AMB's own reviewers: 2 of the 14 on-record reviews state a quoted window and what happened against it. The reviews are reproduced in full in Block 11.

Block 2

Headline statistics

Each figure carries the n it was computed from. The n= badge next to a statistic is the number of records it was computed from. Below n=8 the badge is amber. Below n=3 the statistic is suppressed and the individual values are shown instead.

Median purity 99.43% n=203
Interquartile range 0.75pp n=203
10th percentile 98.18% n=203
Pass rate vs index spec 99.5% n=203
Median recovery vs claim 98.0% n=112
Median water 5.01% n=203
Median |mass error| 2.4ppm n=167
Records carrying a flag 19.2% n=203
015304592.093.094.095.096.097.098.099.0100.092.00–92.25 %: n=092.25–92.50 %: n=092.50–92.75 %: n=092.75–93.00 %: n=093.00–93.25 %: n=093.25–93.50 %: n=093.50–93.75 %: n=093.75–94.00 %: n=094.00–94.25 %: n=094.25–94.50 %: n=094.50–94.75 %: n=094.75–95.00 %: n=095.00–95.25 %: n=095.25–95.50 %: n=095.50–95.75 %: n=095.75–96.00 %: n=096.00–96.25 %: n=096.25–96.50 %: n=096.50–96.75 %: n=096.75–97.00 %: n=097.00–97.25 %: n=097.25–97.50 %: n=197.50–97.75 %: n=697.75–98.00 %: n=598.00–98.25 %: n=1398.25–98.50 %: n=998.50–98.75 %: n=698.75–99.00 %: n=1199.00–99.25 %: n=2399.25–99.50 %: n=3799.50–99.75 %: n=4199.75–100.00 %: n=51median 99.43 Purity (% area) Reports
Figure 1. Purity distribution for all 203 AMB records carrying a purity figure. Domain fixed at 92–100 % area and bin width 0.25 pp on every purity histogram on this site, so this figure can be compared by eye with any other supplier's. Dashed line is the AMB median, 99.43 %; the index median is 99.08 %.
Block 3

Reproducibility across independent tests of one lot

Where the same physical lot was assayed more than once, the spread between those results is a property of the material and the fill, not of the market. It is the rarest and most informative statistic on this page, and it exists only for lots someone tested twice.

Median within-batch spread 0.53pp n=25
Index median spread 0.67pp n=28
Lots tested 3+ times 25 n=36

Across the 25 AMB lots in the index with three or more independent assays, the median spread between the highest and lowest purity result on one lot is 0.53 pp. Interpreting that number requires the laboratory repeatability figures: the best contributing laboratory here repeats to 0.16 pp and the worst to 0.34 pp, so a within-lot spread under about 0.5 pp is indistinguishable from measurement noise and a spread above 1 pp is a statement about the material.

Block 4

Supplier certificate against independent measurement

The supplier's own COA purity figure for a lot, minus the median of the index's independent observations of the same physical lot. Positive means the certificate reads higher than the measurement. Rule AX-R05 fires above 1.5 pp.

Median COA divergence +0.15pp n=36
Index median divergence +0.06pp n=28
Divergences in the supplier's favour 72% n=36
Divergences beyond 1 pp 0% n=36
Block 5

Provenance — where the tested material came from

Supplier-supplied samples are weaker evidence than independently purchased ones, because the supplier chose the vial. The index measures the size of that effect rather than assuming it.

Buyer-sourced median 99.43% n=191
Supplier-supplied median suppressed n=1 n<3 — see individual records
Supplier-supplied share of records 0.5% n=203

Too few records in one or both provenance classes (buyer-sourced n=191, supplier-supplied n=1) to compute a provenance gap for AMB. The index-wide effect is +0.31 pp and applies until measured otherwise.

97.397.898.298.799.299.7100.1Buyer-sourcedBuyer-sourced: Q1 99.00, median 99.43, Q3 99.71, n=191outlier 97.48outlier 97.51outlier 97.55outlier 97.59outlier 97.60outlier 97.74outlier 97.74outlier 97.75outlier 97.86outlier 97.89n=191Laboratory-retainedLaboratory-retained: Q1 98.76, median 99.39, Q3 99.84, n=11n=11 Purity (% area)
Figure 2. AMB purity by sample provenance. Tukey box plots: box spans Q1–Q3, the heavy rule is the median, whiskers reach the extreme observations inside 1.5 IQR of the box, and points outside the fences are plotted individually. The vertical line is the AMB overall median. Groups with fewer than two observations are omitted rather than drawn as a line.
Block 6

Documentation completeness

The score is not an opinion about paperwork. Each component is the share of AMB batches in the index whose certificate carries that field, weighted as set out on the scoring rubric.

Documentation score 93/100 n=36
Index median score 85/100 n=28
Certificate fieldBatches carrying itRubric weight
Purity figure stated100%25 points
Analytical method stated (column, gradient, wavelength)75%25 points
Peptide content stated72%20 points
Endotoxin stated33%15 points
Named impurities rather than a total74%15 points
Block 7

Coverage by compound

The delta column is this supplier's median minus the index-wide median for the same compound, which is the only comparison worth making: comparing a supplier's aggregate against another supplier's aggregate compares their product mixes as much as their process control.

CompoundClassReportsMedian %Index median %Δ (pp)Index specPass %
GHRP-6Growth-hormone3299.4599.54-0.0999.097
SemaglutideIncretin2498.8798.89-0.0297.0100
TirzepatideIncretin2398.2098.55-0.3597.0100
CJC-1295 (no DAC)Growth-hormone2099.5399.09+0.4498.0100
IpamorelinGrowth-hormone1799.6799.47+0.2099.0100
RetatrutideIncretin1398.1898.37-0.1996.5100
AOD-9604Metabolic1399.4999.29+0.2098.0100
EpitalonShort1299.8999.56+0.3399.0100
PT-141 (Bremelanotide)Melanocortin-receptor1099.8399.38+0.4598.5100
SermorelinGrowth-hormone7 n=799.1199.06+0.0598.0100
SS-31 (Elamipretide)Metabolic7 n=799.5499.53+0.0198.5100
SemaxNeuroactive7 n=799.9299.46+0.4698.5100
Thymosin α1Tissue-repair5 n=599.1199.40-0.2997.5100
TB-500Tissue-repair4 n=499.7699.53+0.2398.5100
OxytocinHypothalamic3 n=399.4499.81-0.3898.5100
L-Glutathione (reduced)Short3 n=399.7999.33+0.4698.5100
MOTS-cMetabolic2 n=2n<399.1398.0100
CJC-1295 with DACGrowth-hormone1 n=1n<398.9597.5100

Full per-compound breakdown with distributions and caveats →

97.397.898.298.799.299.7100.1GHRP-6GHRP-6: Q1 99.36, median 99.45, Q3 99.67, n=32outlier 98.81n=32SemaglutideSemaglutide: Q1 98.48, median 98.87, Q3 99.33, n=24n=24TirzepatideTirzepatide: Q1 97.81, median 98.20, Q3 98.66, n=23n=23CJC-1295 (no DAC)CJC-1295 (no DAC): Q1 99.32, median 99.53, Q3 99.67, n=20n=20IpamorelinIpamorelin: Q1 99.50, median 99.67, Q3 99.86, n=17n=17RetatrutideRetatrutide: Q1 98.15, median 98.18, Q3 98.31, n=13outlier 97.75outlier 97.86outlier 98.67n=13AOD-9604AOD-9604: Q1 99.39, median 99.49, Q3 99.66, n=13n=13EpitalonEpitalon: Q1 99.39, median 99.89, Q3 99.93, n=12n=12PT-141 (Bremelanotide)PT-141 (Bremelanotide): Q1 99.74, median 99.83, Q3 99.93, n=10outlier 99.45n=10SermorelinSermorelin: Q1 99.08, median 99.11, Q3 99.20, n=7outlier 99.38n=7SS-31 (Elamipretide)SS-31 (Elamipretide): Q1 99.44, median 99.54, Q3 99.69, n=7n=7SemaxSemax: Q1 99.79, median 99.92, Q3 99.93, n=7outlier 99.53n=7Thymosin α1Thymosin α1: Q1 99.08, median 99.11, Q3 99.31, n=5outlier 99.93n=5TB-500TB-500: Q1 99.63, median 99.76, Q3 99.86, n=4n=4 Purity (% area)
Figure 3. AMB purity by compound, for the 14 compounds with at least four AMB records. Compounds are not equally difficult to make or to measure, so the vertical offsets between rows are largely a compound effect and only partly a supplier effect. Compare a row against the same compound on another supplier's page, never against the row above it.
Block 8

Quarterly trend

Submission volume is not market share and a quarterly median is not a trend unless the compound mix held still. Both caveats apply to every row below.

Median purity by quarter

Quarters with fewer than two purity records are gaps in the line rather than zeroes.

Coverage growth

Records added per quarter. Growth here is index coverage, not supplier volume.

QuarterBatchesReportsMedian purityRangeFlagged
2024-Q11398.2398.10–98.410
2024-Q200n<30
2024-Q300n<30
2024-Q421199.7699.50–99.930
2025-Q111n<31
2025-Q222199.6899.02–99.934
2025-Q396599.5097.75–99.937
2025-Q452599.2298.43–99.9313
2026-Q141199.6699.40–99.931
2026-Q263099.4198.57–99.934
2026-Q363698.3097.48–99.939

Full quarterly timeline, batch by batch →

Block 9

Which laboratory produced these numbers

Laboratories disagree with each other by a measured amount. A supplier tested mostly by one laboratory carries that laboratory's offset in its aggregate, and the adjusted column removes it.

LaboratoryReportsMedian purityLab bias (pp)Bias-adjusted
Janoshik9899.43+0.0099.43
PeptideMeter3199.38-0.0599.43
Medutest2499.50+0.0899.42
VendorInvestigate1899.13-0.1199.24
Nordanalyt1699.35+0.0299.33
Kestrel1699.91+0.2499.67

Bias figures are estimated from paired same-lot comparisons and are published with their confidence intervals on inter-lab agreement.

Block 10

What this data does and does not show

Block 11

On-the-record reviews 14

Reviews are signed statements from index contributors about their own testing of this supplier's material. They are opinions attached to evidence, and they are not used in any statistic on this page.

95.0/ 100882 ratings across the index network
c-adeyemi98/100

Consistency: 8 lots, purity band under 0.8 points wide. Janoshik report held on file, figures match published.

c-asante97/100

Certificate carries counter-ion identity and content as a figure with units, reported as acetate. Complete against the index minimum data set at first issue. Research use. Not for human administration.

c-batista98/100

Lot AMB-26-118 submitted to Janoshik. Declared 98.8%, reported 99.0%. Delta inside method repeatability. Janoshik report held on file.

c-danquah95/100

Transit 9 days from stock held in Netherlands against a quoted 10. Customs documentation correct at first presentation.

c-ekstrom98/100

Release signed and dated, named individual. Per-milligram figure calculated against the certificate rather than against nominal fill.

c-espinoza80/100

Analytical record complete and unremarkable. Logistics observation logged separately: two of three ordered lines not held in regional stock, dispatched from Beijing, sixteen days elapsed against a quoted seven to ten. Position confirmed on enquiry. Rating reflects the logistics observation only.

c-halonen96/100

Related-substances table itemised by impurity with assigned retention times. Not aggregated. Submitted to the index in full.

c-ilunga97/100

Blind submission of semaglutide 5 mg to Medutest, origin withheld. 98.7% against 98.5% declared. Figures as reported by the named service.

d-aalto96/100

Fill uniformity: 12 units weighed against declared fill, all within 2%. No further comment.

d-antonsen98/100

Cross-check: PeptideMeter and VendorInvestigate, same lot, agreement to 0.1 points. Both agree with the declared figure. Record covers one lot.

d-batista94/100

Batch record supplied in full on request, attached rather than summarised, carrying the release signature. Independent verification of individual lots still required.

d-guerrero91/100

Reconstitution: 8 of 9 units clear on contact, 1 transient haze resolving on standing. Single consignment. Logged as an observation, not a finding.

k-bakken97/100

Cold chain intact. Phase-change pack solid at arrival, day 9. Evidence base adequate for a rating on this criterion.

k-castellanos98/100

Retention: certificate reissued for a lot released 13 months earlier, from supplier records, no justification required. Record covers documentation practice, not material.

Block 12

Most recent records

The 25 most recently submitted AMB records. All 203 are listed on the full record listing.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042002SemaglutideAMB-2607-N6274VendorInvestigate2026-Q398.236.3797.1Buyer-sourced1MARGINAL
AX-2026-042012GHRP-6AMB-2603-S5667Janoshik2026-Q399.375.9088.8Laboratory-retained1MARGINAL
AX-2026-041974TirzepatideAMB-2603-C5112Nordanalyt2026-Q398.203.41Buyer-sourced0PASS
AX-2026-041975TirzepatideAMB-2603-C5112Medutest2026-Q397.883.45106.9Laboratory-retained0PASS
AX-2026-042005SemaglutideAMB-2607-N6274PeptideMeter2026-Q398.096.4898.6Buyer-sourced1MARGINAL
AX-2026-042008EpitalonAMB-2602-Y6433Janoshik2026-Q399.308.75105.1Buyer-sourced0PASS
AX-2026-042021TB-500AMB-2602-P5987VendorInvestigate2026-Q399.864.79101.4Buyer-sourced0PASS
AX-2026-042015GHRP-6AMB-2603-S5667Janoshik2026-Q399.546.4497.1Buyer-sourced0PASS
AX-2026-042009EpitalonAMB-2602-Y6433VendorInvestigate2026-Q399.168.62102.3Buyer-sourced0FAIL
AX-2026-041978TirzepatideAMB-2603-C5112Janoshik2026-Q397.943.57103.0Buyer-sourced0PASS
AX-2026-041982TirzepatideAMB-2603-C5112Janoshik2026-Q397.604.46Buyer-sourced0PASS
AX-2026-042004SemaglutideAMB-2607-N6274Medutest2026-Q397.746.45Buyer-sourced1MARGINAL
AX-2026-042020TB-500AMB-2602-P5987Janoshik2026-Q399.534.6696.8Buyer-sourced0PASS
AX-2026-041972TirzepatideAMB-2603-C5112Janoshik2026-Q398.463.69Buyer-sourced0PASS
AX-2026-041977TirzepatideAMB-2603-C5112Nordanalyt2026-Q398.184.0892.4Laboratory-retained0PASS
AX-2026-042010EpitalonAMB-2602-Y6433Janoshik2026-Q399.098.20103.4Laboratory-retained0FAIL
AX-2026-041990RetatrutideAMB-2606-N5977Janoshik2026-Q398.314.23Buyer-sourced0PASS
AX-2026-041992RetatrutideAMB-2606-N5977VendorInvestigate2026-Q398.173.7796.4Buyer-sourced0PASS
AX-2026-041973TirzepatideAMB-2603-C5112Janoshik2026-Q398.293.4392.0Buyer-sourced0PASS
AX-2026-041991RetatrutideAMB-2606-N5977Janoshik2026-Q398.204.00Buyer-sourced0PASS
AX-2026-042013GHRP-6AMB-2603-S5667Kestrel2026-Q399.935.75Buyer-sourced0PASS
AX-2026-041976TirzepatideAMB-2603-C5112Janoshik2026-Q397.744.2196.8Buyer-sourced0PASS
AX-2026-041971TirzepatideAMB-2603-C5112Janoshik2026-Q397.553.83Buyer-sourced0PASS
AX-2026-042017GHRP-6AMB-2603-S5667Medutest2026-Q399.766.4297.4Buyer-sourced0PASS
AX-2026-042019GHRP-6AMB-2603-S5667PeptideMeter2026-Q398.816.11Buyer-sourced0FAIL
Block 13

Contributor annotations on AMB records 414

Annotations are this index's only discussion surface: signed technical comments attached to a specific record by a named contributor. They are not moderated for agreement with the index's own arithmetic. The most recent on AMB material are below, each linked to the record it sits on.

Both the theoretical and the observed monoisotopic mass are in the published dataset, so the ppm figure can be re-derived rather than trusted. That is the intent of publishing both.
Identity confirmed and purity at 98.23 %. The two answer different questions — what it is, and how much else is in it — and a record carrying both is the version worth citing.
Incomplete salt exchange leaves two counter-ions in the cake and only one gets measured. That is the commonest way a real balance acquires a genuine remainder.
Core-shell packing at 2.6 µm gains roughly 40 % in resolution over a 5 µm fully porous bed at the same length and pressure. On a pair this close, that is the difference between two peaks and one.
The certificate for AMB-2603-S5667 carries a named related-substances table rather than a totals line. That is what makes 99.37 % checkable against this record instead of merely comparable to it.
Column chemistry flatters or punishes a figure like this. A core-shell column at this gradient resolves the close-eluting family that a fully porous 5 µm bed merges, so 99.37 % here is a harder number than the same figure from a coarser column.
If the nearest impurity carries an aromatic residue the parent lacks, dual-wavelength detection separates them without any chromatographic change at all. Cheap and underused.
Every named impurity on this record has a mass defect consistent with its structural assignment. That is the check that distinguishes an assignment from a guess.

Every annotation the index holds on AMB material sits on its own record; the full set is reachable from the record listing and from each contributor's page. To read them against what AMB itself publishes, open ambiopharm.net → alongside.

Block 14

Where to buy AMB

AmbioPharm, Inc. sells direct from ambiopharm.net. Everything on this page describes lots the index has already seen; the certificate that matters is the one that arrives with the vial you order, and the lot code on it should match the vial. Ask for the lot-specific document rather than the batch-level summary, and ask for the integration report if you intend to reconcile the figure yourself.

Go to the AMB store at ambiopharm.net →

Marked nofollow and sponsored. The index is paid nothing for it, takes no commission, and a link is not an assessment. Research compounds. Not medical advice. Nothing on this site is a safety assessment and nothing on it is approved for human use.