AssayIndex

QSC-2412-D8748

BPC-157 · 5 mg declared · Qingdao Sigma Chemical Co., Ltd. · manufactured 25 Dec 2024

CHARACTERISED
Lot code
QSC-2412-D8748
Supplier
QSC — Qingdao Sigma Chemical Co., Ltd.
Compound
BPC-157
Compound class
Tissue-repair and immunomodulatory peptides
Declared label claim
5mg
Manufacture date
25 Dec 2024
Index quarter
2025-Q1
Independent assays
11
Laboratories involved
Janoshik, Kestrel, Nordanalyt, VendorInvestigate, PeptideMeter, Medutest
Provenance mix
Buyer-sourced ×2 · Supplier-supplied ×8 · Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 11
Median purity 99.31% n=11
Spread (max − min) 1.02pp n=11
Standard deviation 0.434pp n=11
96.897.397.998.599.099.6100.2This lot (QSC-2412-D8748)This lot (QSC-2412-D8748): Q1 99.02, median 99.31, Q3 99.85, n=11n=11All BPC-157All BPC-157: Q1 98.59, median 99.15, Q3 99.71, n=591n=591 Purity (% area)
Figure 1. This lot's independent purity results against the whole BPC-157 record set in the index. The vertical line is the index acceptance specification for the tissue-repair and immunomodulatory peptides class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 11

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-018839QSC-2412-D8748Janoshik2025-Q199.176.81Laboratory-retained1MARGINAL
AX-2025-018840QSC-2412-D8748Kestrel2025-Q199.935.87Supplier-supplied0PASS
AX-2025-018841QSC-2412-D8748Janoshik2025-Q199.065.43Supplier-supplied1MARGINAL
AX-2025-018842QSC-2412-D8748Janoshik2025-Q199.315.9588.8Supplier-supplied1MARGINAL
AX-2025-018843QSC-2412-D8748Janoshik2025-Q199.775.4995.1Supplier-supplied1MARGINAL
AX-2025-018844QSC-2412-D8748Janoshik2025-Q199.675.80Supplier-supplied0PASS
AX-2025-018845QSC-2412-D8748Nordanalyt2025-Q199.935.80101.7Supplier-supplied0PASS
AX-2025-018846QSC-2412-D8748VendorInvestigate2025-Q198.915.6898.9Buyer-sourced0PASS
AX-2025-018847QSC-2412-D8748VendorInvestigate2025-Q198.976.00105.3Buyer-sourced1MARGINAL
AX-2025-018848QSC-2412-D8748PeptideMeter2025-Q198.925.5389.6Supplier-supplied1MARGINAL
AX-2025-018849QSC-2412-D8748Medutest2025-Q199.935.83106.5Supplier-supplied1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik599.17, 99.06, 99.31, 99.77, 99.6799.3130min+0.0099.31
Kestrel199.9399.9315min+0.2499.69
Nordanalyt199.9399.9335min+0.0299.91
VendorInvestigate298.91, 98.9798.9432min-0.1199.05
PeptideMeter198.9298.9228min-0.0598.97
Medutest199.9399.9325min+0.0899.85

This lot contributes 15 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.7399.17divergence +0.42 pp vs batch median
Total impurities (% area)0.270.83
Largest single impurity (% area)not stated0.36
Water (%)not stated6.81
Counter-ion (%)5.36.24
Peptide content (%w/w)98.0not determined
Endotoxin (EU/mg)1.32not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
acetylated N-terminus (+42 Da)11 / 110.300.03–0.73
des-Gly truncate (−57 Da)10 / 110.090.02–0.45
pyroglutamate cyclisation (−17 Da)7 / 110.020.02–0.02
truncated (1-12)6 / 110.030.01–0.04
BPC-157 arginine-salt artefact5 / 110.140.04–0.22
[D-Val]-diastereomer4 / 110.120.05–0.14
Section 7

What this rollup does not establish