AssayIndex
Cross-section

BPC-157 by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for BPC-157, with a class minimum gradient of 15 min, the method is a live explanation.

591 recordsmedian 99.15 %spec 98.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik27730minHigh99.13+0.0099.13ADEQUATE
PeptideMeter11128minHigh98.94-0.0598.99ADEQUATE
Medutest8025minUnit99.30+0.0899.22ADEQUATE
VendorInvestigate5132minHigh98.79-0.1198.90ADEQUATE
Kestrel3915minUnit99.61+0.2499.37ADEQUATE
Nordanalyt3335minHigh99.36+0.0299.34ADEQUATE
96.897.397.998.599.099.6100.2JanoshikJanoshik: Q1 98.53, median 99.13, Q3 99.78, n=277n=277PeptideMeterPeptideMeter: Q1 98.48, median 98.94, Q3 99.56, n=111n=111MedutestMedutest: Q1 98.89, median 99.30, Q3 99.72, n=80n=80VendorInvestigateVendorInvestigate: Q1 98.03, median 98.79, Q3 99.28, n=51n=51NordanalytNordanalyt: Q1 98.69, median 99.36, Q3 99.77, n=33n=33KestrelKestrel: Q1 99.06, median 99.61, Q3 99.91, n=39n=39 Purity (% area)
Figure. BPC-157 purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.