Backpressure
The pressure the pump develops to push mobile phase through the column. Rising backpressure across a sequence indicates a blocking frit or a fouled column inlet.
Baseline
The detector signal in the absence of an eluting analyte. On a gradient it drifts, and where the baseline is drawn determines the integrated area.
Base peak
The most intense peak in a spectrum. For a 4 kDa peptide by electrospray it is usually the 4+ charge state.
Bacterial endotoxin
Lipopolysaccharide from gram-negative bacterial outer membranes. Pyrogenic, filter-passing, autoclave-stable, and invisible to every chromatographic method.
Bioburden
The viable microbial count in a non-sterile article. Distinct from sterility, which is a presence/absence test.
Bland–Altman analysis
Paired comparison of two measurement methods by plotting difference against mean. Yields a bias and limits of agreement. Used for inter-lab agreement here.
Bias
A systematic offset between a measurement and a reference. Distinct from scatter: bias in one direction across many observations is a different finding from random disagreement.
Bootstrap
Estimating a confidence interval by resampling the observed data. Useful where a supplier cell is too small for a parametric interval.
Buyer-sourced
Purchased through the supplier's ordinary retail channel by the submitter, with no supplier involvement. The strongest provenance class here.
see also Provenance
Batch rollup
All reports in the index for one physical lot, with a reproducibility assessment across independent tests.
Bacteriostatic water
Water containing 0.9 % benzyl alcohol as a preservative. The benzyl alcohol absorbs strongly in the UV and adds peaks to a chromatogram.