AX-2024-004406
Retatrutide · 12 mg declared · Qingdao Sigma Chemical Co., Ltd. · lot QSC-2408-X8779
- Report ID
- AX-2024-004406
- Compound
- Retatrutide
- Compound class
- Incretin analogues and co-agonists
- Supplier
- QSC — Qingdao Sigma Chemical Co., Ltd.
- Batch / lot
- QSC-2408-X8779
- Declared label claim
- 12mg
- Laboratory
- Janoshik Analytical
- Assay date
- 22 Nov 2024
- Submitted
- 13 Dec 2024
- Quarter
- 2024-Q4
- Submitter
- el.halonen
- Sample provenance
- Supplier-supplied
Results
Measured against the index acceptance specification for the incretin analogues and co-agonists class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.
| Parameter | Method | Result | Unit | Index spec | |
|---|---|---|---|---|---|
| Purity | RP-HPLC, 30 min gradient, 214 nm | 98.67 | % area | ≥ 96.5 | PASS |
| Total impurities | RP-HPLC, sum of reported peaks | 1.33 | % area | ≤ 3.5 | PASS |
| Largest single impurity | RP-HPLC — oxidised Trp (+16 Da) | 0.86 | % area | ≤ 1.00 | PASS |
| Identity | not ordered on this submission | not determined | — | required for VERIFIED status | NOT TESTED |
| Total peptide content | by difference from the gravimetric mass balance | 85.09 | %w/w | — | NOT TESTED |
| Target-compound content | total peptide content × purity | 83.96 | %w/w | — | NOT TESTED |
| Gross fill (as weighed) | five-place balance, under nitrogen | 13.66 | mg | 12 mg declared | NOT TESTED |
| Recovered target peptide | gross fill × target content | 11.469 | mg | 12 mg claim | NOT TESTED |
| Recovery against label claim | recovered ÷ claim | 95.6 | % | 90.0 – 110.0 | PASS |
| Water content | Karl Fischer, coulometric, duplicate | 6.29 | % | ≤ 8.0 | PASS |
| Counter-ion (TFA) | anion-exchange ion chromatography | 7.82 | % | ≤ 12.0 | PASS |
| Residual solvent + inorganic residue | estimated — see /methods/residual-solvents-q3c/ | 0.80 | % | — | NOT TESTED |
| Endotoxin | kinetic chromogenic LAL | 1.08 | EU/mg | ≤ 5.0 | PASS |
| Sterility | not ordered on this submission | not determined | — | no growth | NOT TESTED |
| Appearance | visual, diffuse light, black and white background | White lyophilised cake, intact | — | white to off-white intact cake | PASS |
| Reconstitution clarity | reconstituted per submitter procedure | Clear with a single visible fibre | — | clear, no visible particulates | FAIL |
| pH (reconstituted, 1 mg/mL) | potentiometric, two-point calibration | 3.36 | — | 2.5 – 8.0 | PASS |
| Retention time (observed) | RP-HPLC, 30 min gradient | 20.82 | min | 20.71 ± 0.50 (normalised) | PASS |
| Peak asymmetry (10 % height) | Ph. Eur. 2.2.46 | 1.23 | — | 0.80 – 1.50 | PASS |
| Plate count, main peak | N = 5.54 (t/w½)² | 64,092 | — | ≥ 20,000 | PASS |
| Resolution to nearest impurity | vs [D-Aib2]-diastereomer | 0.65 | — | no index criterion | REPORTED |
Chromatogram and peak integration
The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.
| # | Peak | RT | Area (µV·s) | % area | Δ mass (Da) |
|---|---|---|---|---|---|
| 1 | Retatrutide — main peak | 20.82 | 4,795,668 | 98.67 | — |
| 2 | oxidised Trp (+16 Da) | 20.16 | 41,799 | 0.86 | +15.995 |
| 3 | [D-Aib2]-diastereomer | 20.60 | 9,235 | 0.19 | 0.000 |
| 4 | aspartimide (−18 Da) | 21.53 | 7,290 | 0.15 | -18.011 |
| 5 | incomplete Fmoc removal (+222 Da) | 23.23 | 3,888 | 0.08 | +222.068 |
| 6 | des-Aib20 analogue | 20.38 | 1,458 | 0.03 | -85.053 |
| 7 | truncated (5-39) | 18.90 | 972 | 0.02 | -428.201 |
| Closure check — purity + Σ impurities | 100.00 | CLOSES | |||
Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.
Gravimetric mass balance
Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.
| Component | Determination | %w/w of cake |
|---|---|---|
| Water | Karl Fischer | 6.29 |
| Counter-ion (TFA) | ion chromatography | 7.82 |
| Residual solvent + inorganic residue | estimated | 0.80 |
| Total peptide content | by difference | 85.09 |
| Total | 100.00 CLOSES | |
Supplier certificate, as declared
The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.
| Figure | Supplier COA | This report | Index note |
|---|---|---|---|
| Purity (% area) | 99.39 | 98.67 | divergence +0.87 pp vs batch median |
| Total impurities (% area) | 0.61 | 1.33 | |
| Largest single impurity (% area) | 0.35 | 0.86 | |
| Water (%) | not stated | 6.29 | |
| Counter-ion (%) | not stated | 7.82 | |
| Peptide content (%w/w) | 97.7 | 85.09 | |
| Endotoxin (EU/mg) | not stated | 1.08 | |
| Method stated on certificate | YES | — | column, gradient and wavelength given |
Provenance and caveats
Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.
- Sample provenance
- Supplier-supplied
- Evidentiary weight
- Weaker evidence. Read with the caveat below.
- Chain of custody
- Supplier despatch → laboratory direct (courier, cold pack, 3 d) → assay. Submitter did not handle the vial.
- Assay date
- 22 Nov 2024
- Submitted to the index
- 13 Dec 2024
- Laboratory
- Janoshik Analytical, Ostrava, Czechia
- Method basis
- 30 min gradient · high-resolution MS
- Verification status
- PURITY ONLY
Annotations
No annotations on this record. Annotations are short signed technical comments from index contributors; see how to contribute.
Related records
Same batch — lot QSC-2408-X8779 n=9
| Report | Lot | Lab | Quarter | Purity % | Water % | Recovery % | Provenance | Flags | Result |
|---|---|---|---|---|---|---|---|---|---|
| AX-2024-004404 | QSC-2408-X8779 | Medutest | 2024-Q4 | 98.43 | 5.65 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2024-004405 | QSC-2408-X8779 | Janoshik | 2024-Q4 | 98.60 | 5.76 | 93.3 | Supplier-supplied | 2 | FAIL |
| AX-2024-004407 | QSC-2408-X8779 | Janoshik | 2024-Q4 | 98.67 | 4.99 | 100.6 | Supplier-supplied | 1 | MARGINAL |
| AX-2024-004408 | QSC-2408-X8779 | Janoshik | 2024-Q4 | 98.50 | 5.82 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2024-004409 | QSC-2408-X8779 | Janoshik | 2024-Q4 | 98.52 | 5.03 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2024-004410 | QSC-2408-X8779 | VendorInvestigate | 2024-Q4 | 98.08 | 5.42 | — | Buyer-sourced | 1 | MARGINAL |
| AX-2024-004411 | QSC-2408-X8779 | PeptideMeter | 2024-Q4 | 98.82 | 5.53 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2024-004412 | QSC-2408-X8779 | VendorInvestigate | 2024-Q4 | 97.85 | 5.87 | — | Buyer-sourced | 1 | MARGINAL |
Cross-sections
| Report | Supplier | Lot | Lab | Quarter | Purity % | Water % | Recovery % | Provenance | Flags | Result |
|---|---|---|---|---|---|---|---|---|---|---|
| AX-2026-043029 | KP | KP-2607-H5219 | Medutest | 2026-Q3 | 95.45 | 5.71 | — | Supplier-supplied | 2 | FAIL |
| AX-2026-043030 | KP | KP-2607-H5219 | Kestrel | 2026-Q3 | 95.97 | 6.95 | 97.1 | Supplier-supplied | 2 | FAIL |
| AX-2026-041453 | QYB | QYB-2604-B5660 | VendorInvestigate | 2026-Q3 | 98.02 | 2.55 | — | Buyer-sourced | 1 | MARGINAL |
| AX-2026-041454 | QYB | QYB-2604-B5660 | Janoshik | 2026-Q3 | 98.84 | 2.77 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2026-041538 | QYB | QYB-2602-G6308 | Medutest | 2026-Q3 | 98.50 | 2.85 | — | Supplier-supplied | 2 | MARGINAL |
| AX-2026-041456 | QYB | QYB-2604-B5660 | Janoshik | 2026-Q3 | 98.23 | 3.24 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2026-041452 | QYB | QYB-2604-B5660 | Nordanalyt | 2026-Q3 | 98.50 | 3.36 | — | Supplier-supplied | 1 | MARGINAL |
| AX-2026-043039 | KP | KP-2607-H5219 | Janoshik | 2026-Q3 | 96.14 | 5.62 | — | Supplier-supplied | 2 | FAIL |
| Report | Compound | Lot | Lab | Quarter | Purity % | Water % | Recovery % | Provenance | Flags | Result |
|---|---|---|---|---|---|---|---|---|---|---|
| AX-2026-041683 | CJC-1295 (no DAC) | QSC-2606-V8637 | Janoshik | 2026-Q3 | 99.93 | 3.63 | 97.1 | Supplier-supplied | 1 | FAIL |
| AX-2026-041727 | CJC-1295 with DAC | QSC-2602-E9474 | Janoshik | 2026-Q3 | 98.88 | 6.62 | 105.3 | Supplier-supplied | 1 | MARGINAL |
| AX-2026-041728 | CJC-1295 with DAC | QSC-2602-E9474 | VendorInvestigate | 2026-Q3 | 98.42 | 7.04 | — | Buyer-sourced | 1 | MARGINAL |
| AX-2026-041734 | CJC-1295 with DAC | QSC-2602-E9474 | Medutest | 2026-Q3 | 99.43 | 7.17 | 105.5 | Supplier-supplied | 2 | FAIL |
| AX-2026-041652 | Liraglutide | QSC-2605-W8602 | Nordanalyt | 2026-Q3 | 99.33 | 6.55 | — | Supplier-supplied | 0 | PASS |
| AX-2026-041730 | CJC-1295 with DAC | QSC-2602-E9474 | PeptideMeter | 2026-Q3 | 98.79 | 6.93 | 95.4 | Supplier-supplied | 1 | MARGINAL |
| AX-2026-041686 | CJC-1295 (no DAC) | QSC-2606-V8637 | Janoshik | 2026-Q3 | 99.93 | 4.04 | — | Supplier-supplied | 0 | PASS |
| AX-2026-041653 | Liraglutide | QSC-2605-W8602 | VendorInvestigate | 2026-Q3 | 98.82 | 5.95 | — | Buyer-sourced | 0 | PASS |