AssayIndex

AX-2026-043624

L-Glutathione (reduced) · 600 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · lot WXT-2605-B5720

FAILPURITY ONLY
Report ID
AX-2026-043624
Compound
L-Glutathione (reduced)
Compound class
Short bioregulator peptides
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Batch / lot
WXT-2605-B5720
Declared label claim
600mg
Laboratory
Nordanalyt Laboratories
Assay date
15 Sep 2026
Submitted
22 Sep 2026
Quarter
2026-Q3
Submitter
z.mensah
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the short bioregulator peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 35 min gradient, 214 nm98.18% area≥ 98.5FAIL
Total impuritiesRP-HPLC, sum of reported peaks1.82% area≤ 1.5FAIL
Largest single impurityRP-HPLC — cysteinyl-glycine (−129 Da)0.88% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance92.41%w/wNOT TESTED
Target-compound contenttotal peptide content × purity90.73%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen696.31mg600 mg declaredNOT TESTED
Recovered target peptidegross fill × target content631.762mg600 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim105.3%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate6.95%≤ 12.0PASS
Counter-ionno ionisable counter-ion expectedN/Anot applicableNOT TESTED
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.64%NOT TESTED
Endotoxinkinetic chromogenic LAL0.60EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureFaint haze, clearing on standingclear, no visible particulatesFAIL
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration7.272.5 – 8.0PASS
Retention time (observed)RP-HPLC, 35 min gradient4.71min4.94 ± 0.20 (normalised)FAIL
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.860.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²76,837≥ 20,000PASS
Resolution to nearest impurityvs S-sulfonate adduct (+80 Da)2.34no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

07041140812112228162 L-Glutathione (reduced)4.71 min · 98.18 % 4.43 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0510152025303540 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 35 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 76,837, and skew follows the reported asymmetry factor of 0.86. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.88 % impurity against a 98.18 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1L-Glutathione (reduced) — main peak4.714,771,85298.18
2cysteinyl-glycine (−129 Da)4.4342,7710.88-129.043
3γ-Glu-Cys (−57 Da)4.5026,2460.54-57.021
4glutathione disulfide (GSSG, +305 Da)5.3213,6090.28+304.984
5S-sulfonate adduct (+80 Da)4.555,8320.12+79.957
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer6.95
Counter-ionnone expected0.00
Residual solvent + inorganic residueestimated0.64
Total peptide contentby difference92.41
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.098.18divergence -0.10 pp vs batch median
Total impurities (% area)2.001.82
Largest single impurity (% area)not stated0.88
Water (%)not stated6.95
Counter-ion (%)not statedN/A
Peptide content (%w/w)91.792.41
Endotoxin (EU/mg)0.720.60
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 25 d) → laboratory (courier, cold pack, 4 d) → assay.
Assay date
15 Sep 2026
Submitted to the index
22 Sep 2026
Laboratory
Nordanalyt Laboratories, Uppsala, Sweden
Method basis
35 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

coa_reader
What would resolve this quickly is the batch record rather than the summary certificate — the in-process chromatogram, the fraction cut, and the reporting threshold applied. Every supplier scorecarded here holds one.
A longitudinal set of retail purchases from one supplier across four quarters is the strongest supplier-level evidence available. Several contributors here are building exactly that.
gc_headspace
Residual is the slot that absorbs solvent and anything else unaccounted. A large residual with no headspace determination behind it is a placeholder rather than a measurement.
ftir_amide_i
Reduced and scrambled forms are different problems with different causes and the report does not distinguish them. A non-reducing against reducing comparison would, and one laboratory in this index offers it.
Section 7

Related records

Same batch — lot WXT-2605-B5720 n=8

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043620WXT-2605-B5720Kestrel2026-Q398.336.74101.9Buyer-sourced1FAIL
AX-2026-043621WXT-2605-B5720Kestrel2026-Q398.636.51105.3Buyer-sourced1MARGINAL
AX-2026-043622WXT-2605-B5720Janoshik2026-Q398.026.81Buyer-sourced1FAIL
AX-2026-043623WXT-2605-B5720VendorInvestigate2026-Q398.026.73106.2Laboratory-retained1FAIL
AX-2026-043625WXT-2605-B5720Janoshik2026-Q397.876.1090.7Buyer-sourced1FAIL
AX-2026-043626WXT-2605-B5720Medutest2026-Q398.226.33100.3Buyer-sourced1FAIL
AX-2026-043627WXT-2605-B5720Janoshik2026-Q397.966.0892.3Buyer-sourced1FAIL
Other recent L-Glutathione (reduced) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041873GSPGSP-2607-N3316Janoshik2026-Q398.457.5594.9Buyer-sourced1FAIL
AX-2026-041870GSPGSP-2607-N3316Nordanalyt2026-Q398.687.6590.5Buyer-sourced0PASS
AX-2026-043627WXTWXT-2605-B5720Janoshik2026-Q397.966.0892.3Buyer-sourced1FAIL
AX-2026-043622WXTWXT-2605-B5720Janoshik2026-Q398.026.81Buyer-sourced1FAIL
AX-2026-043623WXTWXT-2605-B5720VendorInvestigate2026-Q398.026.73106.2Laboratory-retained1FAIL
AX-2026-041872GSPGSP-2607-N3316Medutest2026-Q398.507.78Buyer-sourced1MARGINAL
AX-2026-041875GSPGSP-2607-N3316Janoshik2026-Q398.697.45Buyer-sourced0PASS
AX-2026-041868GSPGSP-2607-N3316Medutest2026-Q398.367.87Buyer-sourced0FAIL
Other recent WXT records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043651PramlintideWXT-2603-D6459PeptideMeter2026-Q398.214.97101.6Buyer-sourced1MARGINAL
AX-2026-043531LeuprolideWXT-2604-K4483Medutest2026-Q399.005.03Buyer-sourced0PASS
AX-2026-043561SemaglutideWXT-2604-C5135Janoshik2026-Q396.964.2291.3Buyer-sourced0FAIL
AX-2026-043627L-Glutathione (reduced)WXT-2605-B5720Janoshik2026-Q397.966.0892.3Buyer-sourced1FAIL
AX-2026-043564SemaglutideWXT-2604-C5135Janoshik2026-Q397.154.44104.7Buyer-sourced0PASS
AX-2026-043533LeuprolideWXT-2604-K4483PeptideMeter2026-Q399.894.94Supplier-supplied0PASS
AX-2026-043556SemaglutideWXT-2604-C5135PeptideMeter2026-Q397.564.3589.6Buyer-sourced1MARGINAL
AX-2026-043539LeuprolideWXT-2604-K4483Nordanalyt2026-Q398.785.31Buyer-sourced0PASS